BTS4000-5V12A Battery testing system Model: BTS4000- 5 V 6 A BatteryTestingSystem SN: CT-4008T -5V6A -S1/164 Items Values Input AC AC 220V/110V ±10% / 50Hz Input power 425 W Resolution AD:16bit; DA:16bit Input impedance ≥1MΩ Voltage CV output range 25mV~5V Min discharge voltage 1V for universal holder,1.5V for 2m cable Accuracy ± 0.05% FS Stability ± 0.05% FS Current Output range/channel Range1: 0.5mA-0.1A; Range2: 0.1A-3A; Range3: 3A-6A Accuracy ± 0.05% FS CV cut-off current Range1: 0.2mA;Range2: 6mA;Range3: 12mA Stability ± 0.05% FS Power Output power/channel 30 W Stability ± 0.1% FS Time Current response time <1ms (10% FS~90% FS) Working step time ≤(365*24)h/step Timeformat-00:00:00.000(h, m, s, ms) Data record Data record conditions Min data record interval:100ms Min voltage change: 10mV Min current change: 0.2mA;6mA;12mA Frequency 10Hz Charge Charge modes CC, CV, CCCV, CP Cut-off condition Voltage, Current, Time, Capacity, Energy, -△V Discharge Discharge modes CC, CV, CCCV, CP, CR Cut-off condition Voltage, Current, Time, Capacity, Energy Pulse Charge CC, CP Discharge CC, CP Min pulse width 500ms Pulse counts Up to 32 Chg and Dschg switch Supported Cut-off condition Voltage, Time DCIR Calculated DCIR values available in BTSDA Cycle Max cycles 65535 Max steps 254 Cycle nest 3 Protection Safety protection ● Power-failure data protection ● Offline operation mode ● User-defined protection conditions, such as upper and lower current/voltage, delay time, temperature, etc.
Channels feature Independent pairs of closed loop for constant Channels control mode Independent control Data acquisition method Kelvin connection Noise <55dB Database MySQL Communication TCP/IP Operating system Windows 7/8/10 64bit Data export EXCEL, TXT, CSV, PDF, Plot/Graph Min. disk drive 500GB Communication port Ethernet port Leak Current <5μA Channels per unit 8 Operation and storage environment requirement Items Values Operation environment temperature 0℃~40℃ (When the temperature is 25±10℃, the accuracy offset caused by temperature is less than 50ppm/℃) Storage environment temperature -10℃~50℃ Operation environment humidity ≤70% RH(no moisture condensation) Storage environment humidity ≤80% RH(no moisture condensation).
Product BrochureModel 1. Material code CE-6008n-20V60A-H 2、 Channelsinformation 1. Channels quantity Channels quantity in one unit 8 2. Main channel Channelfeature Constant currentsource and constant voltage source dual closed loop control Channel control mode Independent control Channel parallel connection Supportmax 4 channels parallelmode. Pulse and SIM tests will be disabled in channels parallelmode. 3、Power grid side parameters 1.Input power AC380V±15% 50/60±5Hz 2.Powerfactor ≥99%(Full load) 3.THDi ≤5%(Full load) 4.Inputresistance ≥1MΩ 5.Input power 11.3KW 6.Input current 17.2A/single 7.Overallsystem efficiency(Max) 90% 8.Noise ≤65dB 9.Voltage and current sampling Four-wire connection(same portfor charging and discharging) 10.Power control module type MOSFET 11.Input power wiring method Three-phase-five wire system 12.Powerinput protection Anti-surge, anti-silos, anti over or underfrequency, anti over or under voltage, anti phase absence, etc. 4、Functions and performances 1. Voltage Outputrange Charge:0V~20V Discharge:3V~20V Min discharge voltage 3V,
Accuracy ±0.1% of FS Resolution 24bit 2. Current Outputrange 0.3A~60A Accuracy(independe ntrange) ±0.05% of FS CV cut-off current 60mA Resolution 24bit 3. Power Single channel output power 1.2KW Whole machine output power 9.6KW 4. Time Currentresponse time ≤3ms Current conversion time ≤6ms Min.step time 0.1s 5. Charge/Discharge modes Charge/Discharge modes CCC, CVC, CC-CVC, CPC CCD, CVD, CPD, CRD Cut-off condition Voltage, Current, ΔTime,Capacity, -ΔV 6. Simulation Charge Current, Power Discharge Current, Power Switch Support continuousswitching between charge and discharge Cut-off condition Time,step line Stepsfile lines 1,000,000 7. Pulse Mode Charge Current ,power Discharge Current, Power Min pulse 100ms Pulse counts Up to 32 Charge and discharge switch supported Cut-off condition Voltage,ΔTime 8. DCIR DCIRby calculation 9. Safely protection Software protection Power off data protection Offline mode function Safety protection conditions can be set, including:voltage lowerlimit,voltage upper limit ,current lowerlimit ,current upperlimit ,delay time, etc. Hardware protection Anti-reverse connection, over-voltage, over-current, over-temperature, etc. 5、Data management and analysis 1. Step setting method Form editing,
2. Data report Recording conditions Minimum time interval: 10ms(connected with AUX channel:100ms) Minimum voltage interval: 0.04V Minimum current interval: 0.12A Recording frequency 100Hz(connected withAUX channel:10Hz) 3. Database MySQL database 4. Data output Excel, Txt 5. Curve type Templates available, customization supported 6. Bar code scanning Support bar-code scanning function Management and traceability of historical data 6、Communication 1. Host computer communication TCP/IP protocol 2. Communication port Ethernet 3. Communication baud rate ofthe testers 1M 4. Host computer communication baud rate 10M~100M adaptive 5. Communication setup Set up a LAN(local area network) through switches and routers 6. Communication expansion(optional) SupportCAN,RS485 communication andBMS communication, with DBCconfiguration function 7、Environmental requirements, dimension and weight 1. Operation environment temperature -10℃~40℃(When the temperature is 25±10℃, the accuracy error caused by temperature change isless than 0.005% of FS per degree) 2. Storage environment temperature -20℃~50℃ 3. Operation environment humidity ≤70% RH(no moisture condensation) 4. Storage environment humidity ≤80% RH(no moisture condensation) 5. Dimension W*D*H 600*800*1300(mm) 6. Weight about 178.4KG 7. Tester Picture(Pictures justforreference.