| Voltage | 5V DC |
| Rated Voltage | 2 Volt |
| Model Name/Number | BTS4000-5V12A |
| Power Supply | 425 W |
| Weight | 10 KG |
| Charge And Discharge Mode Maximum Power | CC, CV, CCCV, CP |
| Temperature | -10 C ~50 C |
| Dimension | 3U19 , 483*404*130 |
| Operating Temperature | 0 C~40 C |
| Charge Capacity | CC, CV, CCCV, CP |
| Capacity Discharge | CC, CV, CCCV, CP, CR |
| Brand | NEWARE |
| Usage/Application | Motorcycle |
| Warranty | 1 Year |
| Country of Origin | Made in India |
| Max cycle | 65535 |
| Data expor | EXCEL, TXT, CSV, PDF, Plot/GRAPH |
| Communication port | Ethernet port |
| Operating system | Windows 7/8/10 64bit |
| Dimensions(W*D*H)(mm) | 3U19 , 483*404*130 |
BTS4000-5V12A Battery testing system Model: BTS4000- 5 V 6 A BatteryTestingSystem SN: CT-4008T -5V6A -S1/164 Items Values Input AC AC 220V/110V ±10% / 50Hz Input power 425 W Resolution AD:16bit; DA:16bit Input impedance ≥1MΩ Voltage CV output range 25mV~5V Min discharge voltage 1V for universal holder,1.5V for 2m cable Accuracy ± 0.05% FS Stability ± 0.05% FS Current Output range/channel Range1: 0.5mA-0.1A; Range2: 0.1A-3A; Range3: 3A-6A Accuracy ± 0.05% FS CV cut-off current Range1: 0.2mA;Range2: 6mA;Range3: 12mA Stability ± 0.05% FS Power Output power/channel 30 W Stability ± 0.1% FS Time Current response time <1ms (10% FS~90% FS) Working step time ≤(365*24)h/step Timeformat-00:00:00.000(h, m, s, ms) Data record Data record conditions Min data record interval:100ms Min voltage change: 10mV Min current change: 0.2mA;6mA;12mA Frequency 10Hz Charge Charge modes CC, CV, CCCV, CP Cut-off condition Voltage, Current, Time, Capacity, Energy, -△V Discharge Discharge modes CC, CV, CCCV, CP, CR Cut-off condition Voltage, Current, Time, Capacity, Energy Pulse Charge CC, CP Discharge CC, CP Min pulse width 500ms Pulse counts Up to 32 Chg and Dschg switch Supported Cut-off condition Voltage, Time DCIR Calculated DCIR values available in BTSDA Cycle Max cycles 65535 Max steps 254 Cycle nest 3 Protection Safety protection ● Power-failure data protection ● Offline operation mode ● User-defined protection conditions, such as upper and lower current/voltage, delay time, temperature, etc.
Channels feature Independent pairs of closed loop for constant Channels control mode Independent control Data acquisition method Kelvin connection Noise <55dB Database MySQL Communication TCP/IP Operating system Windows 7/8/10 64bit Data export EXCEL, TXT, CSV, PDF, Plot/Graph Min. disk drive 500GB Communication port Ethernet port Leak Current <5μA Channels per unit 8 Operation and storage environment requirement Items Values Operation environment temperature 0℃~40℃ (When the temperature is 25±10℃, the accuracy offset caused by temperature is less than 50ppm/℃) Storage environment temperature -10℃~50℃ Operation environment humidity ≤70% RH(no moisture condensation) Storage environment humidity ≤80% RH(no moisture condensation).